(Summary description)First of all, the dual-shaft dust humidifier strictly implements the operating procedures to achieve no-load start and no-load stop; to ensure continuous and uniform feeding. Secondly, the technical parameters of the dual-shaft dust humidifier should be selected reasonably, and the speed should not be too large. Then, increase the discharge ope

Double shaft dust humidifier strictly implements operating procedures-dust humidifier manufacturers

(Summary description)First of all, the dual-shaft dust humidifier strictly implements the operating procedures to achieve no-load start and no-load stop; to ensure continuous and uniform feeding. Secondly, the technical parameters of the dual-shaft dust humidifier should be selected reasonably, and the speed should not be too large. Then, increase the discharge ope

  • Categories:Company News
  • Author:
  • Origin:
  • Time of issue:2019-12-11 07:54
  • Views:
Information
First of all, the dual-shaft dust humidifier strictly implements the operating procedures to achieve no-load start and no-load stop; to ensure continuous and uniform feeding. Secondly, the technical parameters of the dual-shaft dust humidifier should be selected reasonably, and the speed should not be too large. Then, increase the discharge opening or lengthen the end of the trough to solve the problem of poor or late discharge. At the same time, a small section of counter-rotating blades can also be installed at the end of the discharge slot to prevent the end from blocking.
         It is also necessary to clean the materials entering the dust humidifier to prevent large impurities or fibrous impurities from entering the machine and causing blockage.
         An anti-blocking valve is opened on the end cover of the unloader. When a blockage occurs, the anti-blocking door is opened due to the accumulation of materials, and the power is cut off by the stroke switch.
         Minimize the lateral size of the intermediate suspension bearing as much as possible to reduce the possibility of material blocking when the material passes through the intermediate bearing. Install silo level device and jam sensor to realize automatic control and alarm.

Scan the QR code to read on your phone

Previous: None
Previous: None

Contact

 

Address: West of North Road, Xin'an Road, Anqiu Economic Development Zone, Weifang, Shandong
Fax:0536-8025333
Mail: sdktyj@163.com
PC: 262100

erweima

Scan mobile site

Copyright: Shandong Kunteng Group      鲁ICP备20002571号-1       Powered by:300.cn